DELEChangzhou Dele Cooling Technology Co., Ltd.
Applications / Livestock ventilation
DELE
Changzhou Dele Cooling Technology Co., Ltd. Changzhou Dele Cooling Technology Co., Ltd.

Livestock ventilation fans

Livestock ventilation fans run more than 8,000 hours a year, and a 1% efficiency gap adds up to thousands of kWh annually. Dele livestock fans focus on efficiency and low maintenance: lubrication-free glass-fibre nylon blades resist ammonia, fitting both negative-pressure and positive-pressure ventilation.

Low-noise wide-chord blades reduce animal stress. Large slow-running impellers of 500–1380 mm are typical, with VFD and two-speed motor options and safety grilles to the required clearances.

Diameter 500–1380 mm Negative / positive pressure Ammonia resistant · lube-free See it in the field ↓

In the Field

On site

From dairy barns to pig houses, Dele fans are installed on gables and sidewalls for continuous negative-pressure exhaust. The large slow impellers move high volumes at low speed and low noise, keeping air fresh without stressing the animals.

Rows of white negative pressure fans on a pig farm sidewall
Sidewall exhaust fansDucted fans in a row along the pig house
Densely arranged fans on a livestock house gable
Gable-mounted fan bankHigh-density fan bank for negative-pressure ventilation
Aerial view of a modern livestock farm
Livestock complexVentilation planned for the whole site

Livestock Ventilation Fans

Products

The impeller is the heart of the fan: wide-chord glass-fibre nylon blades, a corrosion-resistant hub, and a low-speed motor matched to the airflow and static pressure of the house. Blade count and diameter are selected per application.

White livestock fan unit with guard grille
Complete fan with safety grilleWhite housing, grille to required clearances
Six-blade wide-chord glass-filled nylon impeller
Six-blade wide-chord impellerGlass-fibre nylon blades, lube-free and ammonia resistant
Three-blade wide-chord livestock fan impeller
Three-blade impellerLarge chord, high airflow at low rotational speed

Ventilation Layout

System

A ventilation system is more than the fan: inlet area, air speed and the position of the fans decide whether the air actually moves through the animal zone. Dele sizes the fan bank together with the inlet openings and the control strategy.

Pig house ventilation and cooling system section diagram
Pig house ventilation and cooling schematicAirflow, temperature and fan/inlet arrangement in a pig house

Impeller Manufacturing

In house

Blades and hubs are produced and assembled in house, with the same blade-root interface held across batches and materials — so replacements fit and performance stays consistent over years of continuous duty.

Rows of white impellers awaiting assembly in the workshop
Impellers in productionImpeller assemblies lined up in the workshop
Stacked wide-chord blades
Stacked wide-chord bladesBlades ready for hub assembly
Selection notes:

What matters most is long-term reliability and electricity cost. Provide the house cross-section and target air changes, mounting position (gable / ridge / sidewall) and grid frequency; we will size impeller diameter, blade count and speed for the airflow and static pressure.